Blue Prism AD01 - Blue Prism Developer Exam
Page: 3 / 38
Total 190 questions
Question #11 (Topic: Single Topic)
A screen contains four buttons, Find, Save, Close and New. When the buttons are spied, the attributes are identical except for the Window Text attribute.
The values for the Windows Text attribute are "˜Find' for the Find button, "˜Save' for the Save button, "˜Close' for the Close button and "˜New' for the New Button.
The Dynamic Button element has been spied and has the following attributes set:

A navigate stage has been configured to press the Close button:

What additional configuration is required to ensure the Close button is selected by the Navigate stage?
The values for the Windows Text attribute are "˜Find' for the Find button, "˜Save' for the Save button, "˜Close' for the Close button and "˜New' for the New Button.
The Dynamic Button element has been spied and has the following attributes set:

A navigate stage has been configured to press the Close button:

What additional configuration is required to ensure the Close button is selected by the Navigate stage?
A. Set the Mouse Button value to ‘Close’
B. The Params button must be selected and the parameter configured to override the Window Text attribute value to ‘Close’
C. It is not possible to select the Close button using the Dynamic Button element because the value is set to ‘Find’ in the Application Modeller
D. A new element is required with the Window Text value set to ‘Close’ and the Match Type set to equal
Answer: B
Question #12 (Topic: Single Topic)
You identify an element in Application Modeller but when you highlight or use that element Blue Prism gives you an error message saying that duplicate elements
were found.
Which of the following statements is true?
were found.
Which of the following statements is true?
A. It is common for duplicate elements to be found based upon the attributes that are ticked by default using the Blue Prism product. Time needs to be spent experimenting with the attribute ticks until a unique, reliable, and consistent selection of attributes are found.
B. It will not be possible to interface with the element in a unique way. You will need to use Surface Automation techniques for this element.
C. A code stage interface will need to be created and used for this application, this will give you more flexibility to interact with the application elements.
D. You will need to make the attributes you have selected dynamic. This will allow your flow to loop around, incrementing the attribute value until the correct element is found and used. D
Answer: A
Question #13 (Topic: Single Topic)
Which of the following statements about Business Objects is true?
A. It is Blue Prism best practice to include business rules within Business Objects
B. A Business Object is configured in the Studio area of Blue Prism
C. A Business Object can be exposed to Control Room
D. Logging of individual stages is not configurable in Business Objects
Answer: B
Question #14 (Topic: Single Topic)
A Blue Prism solution works fine when developing and testing it in Process and Object studio but when it is running in Control Room exceptions occur because of
screen elements not being found.
What is the most likely cause?
screen elements not being found.
What is the most likely cause?
A. The most likely cause for the errors is that your application has changed.
B. The most likely cause for the errors seen in Control Room is that best practice use of wait stages has not been followed.
C. The most likely cause for the errors is that the Object Studio action has not been published and therefore cannot be used by the Process in control room.
D. The most likely cause for the exceptions is that best practice exception handling has not been incorporated into the Process.
Answer: B
Question #15 (Topic: Single Topic)
The Order System application has been successfully launched and Blue Prism has navigated the application to the following screen:

There is a requirement to ensure this screen is in focus before any further interfacing is done with the screen. Which is the correct configuration to ensure the New
Order screen is in focus?
A.

B.

C.

D.

C

There is a requirement to ensure this screen is in focus before any further interfacing is done with the screen. Which is the correct configuration to ensure the New
Order screen is in focus?
A.

B.

C.

D.

C
Answer: Explanation