VMware 5V0-22.21 - VMware vSAN 6.7 Specialist Exam

Question #11 (Topic: Topic 1)
In a 2-node vSAN cluster, one node has recovered from failure with FTT=1 and RAID-1 storage policy.
Refer to the exhibit:
[VMware-5V0-22.21-1.0/xmlfile-9_1.jpg]
What is the total VMDK storage consumed?
A. 150 GB B. 100GB C. 133GB D. 200GB
Answer: B
Question #12 (Topic: Topic 1)
A vSAN administrator is implementing deduplication and compression on a vSAN all-flash cluster but wants the VMs to remain operational. The details are as
follows:
✑ There are 4 nodes in the vSAN cluster.
✑ Existing VMs use a RAID-5 storage policy.
Which action should the vSAN administrator take to meet this goal?
A. Use explicit fault domains. B. Enable TRIM/UNMAP. C. Change the existing VM storage policy to RAID-6. D. Use the Allow Reduced Redundancy option.
Answer: D
Question #13 (Topic: Topic 1)
A vSAN administrator was presented with 30 additional vSAN ReadyNodes to add to an existing vSAN cluster. There is only one administrator to complete this
task.
What is the fastest approach?
A. Use a Host Profile that was extracted from an existing host. B. Clone the ESXi boot partition to all new hosts, since the hardware is identical. C. Run vim-cmd to capture, and apply the configuration from an existing host. D. Launch Quickstart to Add Hosts to a vSAN Cluster
Answer: D
Question #14 (Topic: Topic 1)
A vSAN administrator has a vSAN cluster that is using vSphere Lifecycle Manager (vLCM) to manage hypervisor, server drivers, and firmware. All hosts in the
cluster are compliant according to the vLCM image.
A 10GB NIC on the servers is experiencing issues, the vSAN administrator determines a new network driver will resolve the problem. Unfortunately, the required
NIC driver is a newer version compared to the driver provided by the most recent Vendor Addon.
Which action should the vSAN administrator take to ensure the latest network driver is installed on the NIC before remediation?
A. Add an individual component to the vLCM image that has the updated NIC driver. B. Since server vendors release periodic server Vendor Addon updates, make sure the vLCM image is configured to use the most recent version of the vendor addon. C. Modify the vLCM image to omit the NIC Driver, and then manually update the servers with the required NIC driver. D. Remove the Vendor Addon from the vLCM image, and then manually install the network driver on the servers.
Answer: A
Question #15 (Topic: Topic 1)
Which tool should be used to identify vSAN unassociated objects?
A. vSphere Host Client B. vSphere CLI C. vsantop D. PowerCLI
Answer: B
Download Exam
Page: 3 / 16
Total 76 questions