Netapp NS0-506 - NetApp Certified Implementation Engineer - SAN, Clustered Data ONTAP Exam
Page: 3 / 15
Total 75 questions
Question #11 (Topic: )
Click the Exhibit button.
cl01::>lun resize vserver
svm1 volume db1_vol lun db1
-size 4096g
Error: command failed: New
size exceeds this LUNs
initial geometry
cl01::>
What is the reason for the error shown in the exhibit?
cl01::>lun resize vserver
svm1 volume db1_vol lun db1
-size 4096g
Error: command failed: New
size exceeds this LUNs
initial geometry
cl01::>
What is the reason for the error shown in the exhibit?
A. The LUN is thin provisioned, but the parent volume is thick provisioned and cannot satisfy the request.
B. The aggregate over commitment threshold has been exceeded.
C. The parent volume that contains the LUN is out of space.
D. The LUN cannot be grown past its maximum resize size.
Answer: D
Question #12 (Topic: )
Click the Exhibit button.
After mapping the LUN on the cluster, you are not able to see in on the Windows 2012
host.
cl01::>igroup show instance
Vserver Name: svm1
Igroup Name: ig1-win
Protocol: iscsi
OS Type: Windows
Portset Binding Igroup: -
Igroup UUID: 358338ba-cfd6-
11df-a9ab-123478563412
Initiators: iqn.1991-
05.com.microsoft: host1 (not
logged in)
Referring to the exhibit, what is the problem?
After mapping the LUN on the cluster, you are not able to see in on the Windows 2012
host.
cl01::>igroup show instance
Vserver Name: svm1
Igroup Name: ig1-win
Protocol: iscsi
OS Type: Windows
Portset Binding Igroup: -
Igroup UUID: 358338ba-cfd6-
11df-a9ab-123478563412
Initiators: iqn.1991-
05.com.microsoft: host1 (not
logged in)
Referring to the exhibit, what is the problem?
A. An administrator is not logged into the host.
B. The iSCSI target has not been added to the host.
C. The OS type should be windows_2008.
D. The OS type should be windows_gpt.
Answer: B
Question #13 (Topic: )
You have a host that loses connectivity to a LUN after a volume is moved from one node to
another in the cluster. You verified that it is not a cluster or a switch problem.
Which two actions will help determine the problem? (Choose two.)
another in the cluster. You verified that it is not a cluster or a switch problem.
Which two actions will help determine the problem? (Choose two.)
A. Verify that MPIO and ALUA are enabled.
B. Verify that the SnapDrive version is supported for the host and Data ONTAP version.
C. Verify the HBA timeout setting.
D. Verify that the SANtricity Storage Manger version is supported on the host.
Answer: A,C
Question #14 (Topic: )
What is a NetApp-recommended zoning best practice?
A. Switch port zoning should always be employed.
B. WWNN zoning is required.
C. Single-initiator zoning is recommended.
D. Zones can overlap.
Answer: C
Question #15 (Topic: )
A customer has recently deployed a clustered Data ONTAP 8.3 system and is trying to
mount LUNs to a Windows 2012 Server using the iSCSI protocol. They have enabled
jumbo frames on their nodes as well as their Windows 2012 Server. Whenever they
attempt to scan for a new LUNs, Disk Management times out and does not present any
new storage.
What is causing the problem?
mount LUNs to a Windows 2012 Server using the iSCSI protocol. They have enabled
jumbo frames on their nodes as well as their Windows 2012 Server. Whenever they
attempt to scan for a new LUNs, Disk Management times out and does not present any
new storage.
What is causing the problem?
A. Windows 2012 does not support jumbo frames with the iSCSI protocol.
B. Clustered Data ONTAP 8.3 does not support the iSCSI protocol.
C. They have jumbo frames enabled on the host and storage, but not the Ethernet switches.
D. Clustered Data ONTAP 8.3 does not support jumbo frames with the iSCSI protocol.
Answer: C