Netapp NS0-182 - NetApp Certified Storage Installation Engineer, ONTAP Exam

Question #6 (Topic: Topic 1)
[Network-NS0-182-1.0/xmlfile-5_1.png]
You just installed two nodes into an existing ONTAP cluster. When running date on the CLI you notice that the cluster1-03 node is running behind time. You
confirmed that you can reach the node management LIF of each node.
Referring to the exhibit, which statement is true?
A. The node-management LIF has to be on e0M for NTP to work. B. The DNS is not configured for this node. C. The NTP is adjusting in small increments. D. No NTP server is configured for this node.
Answer: B
Question #7 (Topic: Topic 1)
When planning the installation of a new ONTAP 9.5 cluster for a customer, which three steps should you perform? (Choose three.)
A. Complete a Service Event Report. B. Use Config Builder to create a configuration spreadsheet. C. Review the hardware components in Hardware Universe. D. Open a support case to prepare for the installation. E. Search for Technical Support bulletins for the hardware.
Answer: ABC
Question #8 (Topic: Topic 1)
Node 3 has taken over Node 4. You are attempting to access Node 4 on its management interface but cannot do it.
In this scenario, how would you access Node 4's management interface?
A. You must use the Service Processor; node management LIFS do not fall over between nodes. B. You have not waited long enough for the failover timeout for a node management LIF; there is a broadcast domain configured for this situation. C. You should use SSH directly to one of the cluster interconnect switches; from there, you can use SSH to the node management on node 4. D. Connect to the node management on Node 3 and then use the HA interconnect to access node 4.
Answer: A
Question #9 (Topic: Topic 1)
You completed the installation of an AFF A700s with NetApp CN1610 switches. You used ports e0a and e0f with breakout cables to connect the controllers to the
interconnect switches. After completing the cluster setup, ports e0e and e0i are not visible in OnCommand System Manager.
In this scenario, what caused this problem?
A. Breakout cables were used and the second port on the same ASIC became disabled. B. This is a hardware error and you must open a case with NetApp Support. C. You must first enable the ports using the network port modify command. D. You are missing a license to enable those ports.
Answer: C
Question #10 (Topic: Topic 1)
A 4-node cluster has connectivity for both block and file access. Nodes 1 and 3 are used for file access, and nodes 2 and 4 are used for block access. During
routine maintenance, node 4 is switched off and the LIFs are migrated to other nodes. Upon investigation, you see that the LIFs that serve file traffic have moved
to alternative ports. However, LIFs that serve the block have not migrated.
In this scenario, what is happening?
A. The failover group is configured incorrectly. B. The fiber switch is configured incorrectly. C. There is a faulty SFP. D. The LIFs that serve the block protocol do not failover.
Answer: B