CompTIA ISS-003 - Intel® Server Specialist Certification Exam Exam

Question #11 (Topic: )
Your customer has asked you the Intel Server Specialist for confirmation onthe
process following changes to their server (additional memory, a different raid card and a
40Gb Ethernet card)? What must they do to ensure accurate monitoring of all the sensors
in their S2600WT based server?
A. The FRU/SDR must be updated with the latest master.cfg to enable the new hardware to be detected. B. They don’t need to do anything - the current firmware will auto-configure. C. The ME must be updated prior to use of the master.cfg and then the FRUSDR update may be carried out. D. Only the FRUneeds to be updated as the SDR now auto-configures E. Only the SDR needs to be updated as the FRU auto-configures.
Answer: B
Question #12 (Topic: )
As an Intel Server Specialist, you are educating your customer on the different memory
offeringsthat are available in the current server generation. How many UDIMMs per
channel can be installed in the Grantley servers?
A. 0 UDIMMs per channel B. 1 UDIMMs per channel C. 2 UDIMMs per channel D. 3 UDIMMs per channel E. 4 UDIMMs per channel
Answer: A
Question #13 (Topic: )
Your customer is in the market to upgrade their HPC infrastructure. Thereforeintegrated
Infiniband is seen to be a base essential and must be down on the board. Please advise
your customer as to which systems could answer their needs from the list below:
A. Intel ® Compute Module HNS2600KP B. Intel ® Compute Module HNS2600TP C. Intel ® Server System R1208WTTGS D. Intel ® Compute Module HNS2600TPF E. Intel ® Server System R2208WTTYC1
Answer: D
Question #14 (Topic: )
Which of the following BIOS setup pages should be entered to disable the NUMA option?
A. Advanced-Processor Configuration B. Advanced-PCI Configuration C. ServerManagement- BMC LAN Configuration D. Advanced-Memory Configuration-Memory RAS and Performance Configuration E. Security Page
Answer: D
Question #15 (Topic: )
What is the correct method of connecting the SGPIO cable to two HSBPs in the current
generation server systems? How would you answer from the list below?
A. In the current generation platform the HSBP does not need an SGPIO B. In the current generation platform the SGPIO is integrated within the data cables C. The first HSBP connects with an SGPIO cable to the system board, the second HSBP connects via SGPIO cable to the first HSBP D. One HSBP connects via SGPIO cable to the system board, the other HSBP connects via SGPIO cable to the RAID controller E. Each HSBP connects with its own cable to the system board
Answer: C
Download Exam
Page: 3 / 37