HP HPE0-S58 - Implementing HPE Composable Infrastructure Solutions Exam

Question #6 (Topic: Topic 1)
Refer to the exhibit.
[HP-HPE0-S58-1.0/xmlfile-5_1.png]
An integrator needs to add an FCoE connection to the server profile, but the FCoE connection type is not available.
What is the likely cause of this issue?
A. FCoE capable interconnect modules are not installed in the Synergy frame B. Defined FCoE network is not associated with a SAN or does not have VLAN Id defined C. A FCoE connection is not available, as there is no LIG configured for FCoE connectivity D. The FCoE connection has not been added as a Fibre Channel connection within a server profile
Answer: D
Question #7 (Topic: Topic 1)
An integrator is installing three Synergy frames in different locations for a customer. As part of the installation, the customer requests a single monitoring
dashboard that shows the current hardware status, warranty status, and open support cases of all three frames.
Which configuration steps must the integrator perform to provide the customer with this functionality?
A. Enable Remote Support and Insight Online Integration in the Composer UI B. Install Insight Remote Support Advanced, and integrate it with HPE Global Dashboard C. Configure OneView with iLO Amplifier pack D. Activate iLO Federation on all installed compute nodes
Answer: C
Question #8 (Topic: Topic 1)
What are valid uses for an IPv4 address pool when configuring an HPE Synergy solution? (Choose two.)
A. assignment of IP addresses for NICs in an operating system B. assignment of IP addresses for Composer appliances C. assignment of IP addresses for PXE booting to a deployment server D. assignment of IP addresses for interconnect modules E. assignment of IP addresses for iLOs
Answer: DE
Question #9 (Topic: Topic 1)
HOTSPOT
A customer has the following HPE Synergy solution:
✑ three Synergy frames
✑ two HPE Virtual Connect SE 32Gb Fibre Channel (FC) modules in each time
✑ two HPE Virtual Connect SE 40GB F8 modules
✑ four HPE Synergy 10Gb Interconnect Link Modules
Click the menu option the integrator should use to add more uplinks ports from HPE Virtual Connect SE 32 Gb FC modules to SAN uplink set.
Hot Area:
[HP-HPE0-S58-1.0/xmlfile-7_5.jpg]
Answer: [HP-HPE0-S58-1.0/xmlfile-8_1.jpg]
Question #10 (Topic: Topic 1)
Which policy can an integrator apply when creating a datastore using HPE OneView for vCenter Server?
A. Data at Rest encryption policy B. Round Robin load balancing policy C. Recovery Manager Central policy D. virtual machine Restart policy
Answer: C
Download Exam
Page: 2 / 20
Total 97 questions