CLARiiON Installation and Troubleshooting Specialist Exam v5.0 (E20-611)

Page:    1 / 9   
Total 133 questions

Which type of SCSI error is a 0x801?

  • A. Hard
  • B. Informational
  • C. Soft
  • D. Uncorrectable


Answer : C

Which utility/command line collects the data needed to analyze a Brocade switch?

  • A. productinfo
  • B. show tech-support details
  • C. supportshow
  • D. tech-support


Answer : C

How many back-end activities have to occur when modifying a single sector on a RAID 5
LUN in a CLARiiON CX4 series array?

  • A. One (1) read, one (1) write
  • B. One (1) write
  • C. Two (2) reads, one (1) write
  • D. Two (2) reads, two (2) writes


Answer : D

Click the Exhibit button.
In which slot is the iSCSI module installed?


  • A. 0
  • B. 1
  • C. 2
  • D. 3


Answer : C

Your customer has discovered that the boot images for both SPA and SPB in their CX3-80 are corrupt and will need re-imaging. The recovery image file was not loaded to the array during the last software upgrade.
What is the file extension for the "reactive" recovery file?

A. ENA -

B. MIF -

C. NDU -

D. PBU -



Answer : B Topic 1, B B

Which CX4 model supports SATA-II drives as vault drives?

  • A. CX4-120
  • B. CX4-240
  • C. CX4-480
  • D. CX4-960


Answer : A

What does the low priority, always running, Sniff Verify operation check?

  • A. A LUN
  • B. The bound space in a RAID group
  • C. The entire bound space in an array
  • D. The specified sectors


Answer : C

Which type of session is required to reset the domain security to an established storage domain?

  • A. FTP
  • B. HyperTerminal
  • C. PPP
  • D. Telnet


Answer : C

Which host failover software is supported with a Non-Disruptive Upgrade (NDU)?

  • A. HP-UX PVLinks, Linux native failover, Microsoft Windows with PowerPath
  • B. HP-UX PVLinks, Solaris with VERITAS DMP, Microsoft Windows with PowerPath
  • C. Linux native failover, HP-UX PVLinks, Solaris with VERITAS DMP
  • D. Microsoft Windows with PowerPath, Linux native failover, Solaris with VERITAS DMP


Answer : A

How many power supplies/blower modules are needed to start mirrored write caching on a
CLARiiON CX4-480?

  • A. 1
  • B. 2
  • C. 3
  • D. 4


Answer : C

How is Write cache mirrored in a CLARiiON array?

  • A. Write data is mirrored through the SP agent over the service port connections.
  • B. Write data is received by the target SP and copied to the peer SP through the CMI bus.
  • C. Write data is sent to each SP from the host and compared through the CMI bus.
  • D. Write data is sent to the target LUN and read back to the peer SP.


Answer : D

Which information is used in the "Magic" 8 Bytes of a formatted sector of a degraded mode
RAID 1/0 group?

  • A. Checksum
  • B. Shed Stamp
  • C. Time Stamp
  • D. Write Stamp


Answer : A

During a CLARiiON conversion the Upgrade Wizard does not start automatically when the
SP is booted to the Utility Partition.
What is the most common problem and resolution?

  • A. The correct Conversion Image NDU package was not installed and the upgrade will need to be completed manually without the Upgrade Wizard.
  • B. The correct Conversion Image NDU package was not installed and the original hardware configuration will need to be swapped back so the correct Conversion Image can be installed.
  • C. The new hardware is not compatible and the original hardware configuration will need to be swapped back until compatible hardware is shipped to the site.
  • D. There is no fifth vault drive and the original hardware configuration will need to be swapped back so the fifth drive can be added to proceed with the conversion.


Answer : B

Your customer is serially connected using PPP from a management station to an array.
What is the maximum baud rate that can be used for a dial-up networking environment?

  • A. 9,600
  • B. 19,200
  • C. 38,400
  • D. 115,200


Answer : B

When does the PSM activate the new software on the secondary storage processor in a
Non-Disruptive Upgrade (NDU)?

  • A. After a successful reboot of the primary storage processor
  • B. After activating it on the primary storage processor
  • C. Before a successful reboot of the service workstation
  • D. Before activating it on the primary storage processor


Answer : D

Page:    1 / 9   