IBM C2010-568 - IBM Tivoli Composite Application Manager for Application Diagnostics V7.1 Implementation Exam

Question #6 (Topic: )
A customer is trying to configure the Data Collector onLinux in Silent mode using this
command:/opt/IBM/ITM/bin/itmcmd config -A -p ynv_silent_config_wasdc.txt ynThe
configuration fails with this error
message:com.ibm.tivoli.itcam.install.was.config.requestaction.ValidateException:Specified
directory "/opt/WebSphere/V61/AppServer/profiles/AppSrvs" is not found, please correct
the value of parameter "DC_CONFIG_SELECT_PROFILE_NONGUI" Why?
A. An invalid value was specified for KYJ_WAS_HOME variable. B. An invalid value was specified for KYN_WAS_HOME variable. C. An invalid value was specified for KYN_CONFIG_MODE variable. D. An invalid value was specified for KYJ_PROFILE_HOME variable.
Answer: B
Question #7 (Topic: )
A customer suspects that the WAS application is having memory issues. How can the
customer monitor heap size usage after garbage collection cycle with IBM Tivoli Composite
Application Manager for Application Diagnostics V7.1 Agent for WebSphere Applications?
A. use a predefined situation: WASOutofHeapSpace B. a custom situation must be created for thecustomer C. use a predefined situation: WASAvgHeapSizeAfterGCHigh D. it is only possible in deep-dive diagnostics using a managing server
Answer: C
Question #8 (Topic: )
Which two areas must be reviewed when examining the project scope of an IBM Tivoli
Composite Application Manager for Application Diagnostics V7.1 implementation project?
(Choose two.)
A. will remote access be provided B. the required level of customization necessary C. application environments that need to be monitored D. the size of the customer's current IBM Tivoli Monitoring environment E. the skill level of the engineers in the company's Information Technology department
Answer: B,C
Question #9 (Topic: )
Which file should be changed in a Tomcat property file for IBM Tivoli Composite Application
Manager for Application Diagnostics V7.1 in order for the logging files location to be
modified for a Data Collector?
A. CYN.handler.FileLoc B. MS.Property.file.LOC C. MS.handler.file.fileDir D. CYN.handler.file.fileDir
Answer: D
Question #10 (Topic: )
AnIBM Tivoli Composite Application Manager for Application Diagnostics V7.1 environment
is being fine tuned at a customer site. Which parameter is likely to be excluded from
changes that are made?
A. datacollector.frequency B. networkagent.publish.frequency C. datacollector.publish.frequency D. network.collector.publish.frequency
Answer: B
Download Exam
Page: 2 / 23
Total 111 questions