Cisco 300-175 - Implementing Cisco Data Center Unified Computing Exam
Page: 3 / 47
Total 233 questions
Question #11 (Topic: Topic 1)
A Cisco UCS Administrator is planning to complete a firmware upgrade using Auto install.
Which two options are prerequisites to run Auto install? (Choose two.)
Which two options are prerequisites to run Auto install? (Choose two.)
A. minor fault fixing
B. configuration backup
C. service profiles unmounted from the blade servers
D. time synchronization
E. fault suppression started on the blade servers
Answer: A,B
Question #12 (Topic: Topic 1)
You need to design and implement a Cisco UCS 5108 Blade Server Chassis system for a
customer.
Which statement about how half-width blades and full-width blades can be used is true?
customer.
Which statement about how half-width blades and full-width blades can be used is true?
A. Only two full-width blades can be installed in the top two slots, and four half-width blades can be installed in the bottom two slots.
B. Only one full-width blade can be installed in the top slot, and six half-width blades can be installed in the bottom slots.
C. Half-width blades and full-width blades can be combined in any order.
D. Half-width blade types and full-width blade types cannot be combined.
Answer: C
Question #13 (Topic: Topic 1)
Which two statements about the service profile configuration options in the Cisco UCS
Manager GUI are true? (Choose two.)
Manager GUI are true? (Choose two.)
A. It can be generated automatically from the service profile template.
B. It can be derived from the chassis discovery policy.
C. It can be derived from the initial template or the updating template.
D. It can be configured by cloning a virtual machine profile.
E. It can be configured by using the chassis connectivity policy.
Answer: B,E
Question #14 (Topic: Topic 1)
Which actions must be taken in order to connect a NetApp FCoE storage system to a Cisco
UCS system?
UCS system?
A. Ensure that the Fibre Channel switching mode is set to Switching, and use the Fibre Channel ports on the Fabric Interconnects.
B. Ensure that the Fibre Channel switching mode is set to Switching, and reconfigure the port to a FCoE Storage port.
C. Ensure that the Fibre Channel switching mode is set to End-Host, and use the Ethernet ports on the Fabric Interconnects.
D. Ensure that the Fibre Channel switching mode is set to Switching, and use the Ethernet ports on the Fabric Interconnects.
Answer: A
Question #15 (Topic: Topic 1)
View the Exhibit.
[Cisco-300-175-8.0/Cisco-300-175-9_2.png]
Refer to the exhibit. Which two media types can you mount from the KVM console?
(Choose two.)
[Cisco-300-175-8.0/Cisco-300-175-9_2.png]
Refer to the exhibit. Which two media types can you mount from the KVM console?
(Choose two.)
A. VHD
B. ISO
C. VMDK
D. IMG
E. VHDx
Answer: B,D