Citrix 1Y0-350 - Citrix NetScaler 10 Essentials and Networking Exam

Question #6 (Topic: )
A network engineer has configured two NetScaler MPX appliances as a high availability
(HA) pair.
What can the engineer configure to prevent failover if only a single interface fails?
A. FIS B. PBR C. SNMP D. VMAC
Answer: A
Question #7 (Topic: )
Scenario: A NetScaler appliance currently has a manually configured channel containing
four interfaces; however, the engineer has been told that the NetScaler must now only use
a single interface for this network. The engineer removes the channel and immediately
notices a decrease in network performance.
How could the engineer resolve this issue?
A. Reset the unused interfaces B. Disable the unused interfaces C. Enable flow control on all interfaces D. Disable HA monitoring on the three interfaces that are no longer required
Answer: B
Question #8 (Topic: )
Scenario: A NetScaler engineer needs to enable access to some web servers running on
an IPv6-only network. The clients connecting the services are on an IPv4 network. The
engineer has already enabled IPv6 on the NetScaler.
What does the engineer need to do in order to provide access to the services on the IPv6
network?
A. Create an IPv6 tunnel and a IPv4 virtual server. B. Configure an IPv6 VLAN and bind the required interface. C. Create a IPv4 virtual server and bind the service group to it. D. Create an IPv6 ACL and a IPv4 virtual server and bind the ACL to the virtual server.
Answer: C
Question #9 (Topic: )
Scenario: A network engineer created an IPv6 virtual server on the NetScaler. The virtual
server is using a service group with two IPv4 servers bound to it. When testing access to
the virtual server from a client configured with an IPv6 address, he is unable to connect.
What could be the reason for this issue?
A. The NetScaler is disabled for NAT. B. IPv6 protocol translation is disabled. C. An IPv6 address on the NetScaler is not bound to the correct VLAN. D. The NetScaler does not have an INAT rule to convert IPv4 to IPv6 from the back-end servers.
Answer: B
Question #10 (Topic: )
Scenario: An engineer executes the following commands:
add vlan 2
bind vlan 2 -ifnum 1/2
add ns ip 10.110.4.200 255.255.255.0
bind vlan 2 -IPAddress 10.110.4.200 255.255.255.0
What type of IP address has been added to the NetScaler?
A. VIP address B. NSIP address C. SNIP address D. GSLB Site IP address
Answer: C
Download Exam
Page: 2 / 26