Netapp NS0-191 - NetApp Certified Support Engineer (NCSE) Exam Exam
Page: 2 / 12
Total 60 questions
Question #6 (Topic: )
Click the Exhibit tab.
[Netapp-NS0-191-8.0/Netapp-NS0-191-4_2.png]
[Netapp-NS0-191-8.0/Netapp-NS0-191-4_3.png]
Your customer's MetroCluster controllers have generated AutoSupport notifications with a
DISK REDUNDANCY FAILED message.
Referring to the exhibit, which component is causing the problem?
[Netapp-NS0-191-8.0/Netapp-NS0-191-4_2.png]
[Netapp-NS0-191-8.0/Netapp-NS0-191-4_3.png]
Your customer's MetroCluster controllers have generated AutoSupport notifications with a
DISK REDUNDANCY FAILED message.
Referring to the exhibit, which component is causing the problem?
A. the SAN switch site3_3
B. the SAN switch site1_2
C. the ATTO bridges on site3
D. the inter-switch link (ISL) between site1 and site3
Answer: D
Question #7 (Topic: )
A hosting company is about to deploy a Microsoft Hyper-V environment connected to
NetApp storage. They want to know which version of SMB and Data ONTAP should be
deployed in this environment that supports continuously available shares.
In this scenario, what do you tell the customer?
NetApp storage. They want to know which version of SMB and Data ONTAP should be
deployed in this environment that supports continuously available shares.
In this scenario, what do you tell the customer?
A. Data ONTAP 7-Mode and SMB3
B. clustered Data ONTAP and SMB3
C. clustered Data ONTAP and SMB 2.1
D. Data ONTAP 7-Mode and SMB 2.1
Answer: B
Question #8 (Topic: )
A 2-node cluster (Node-1 and Node-2) has suffered a takeover event. The down node
(Node-1) is currently waiting for giveback. However, it is ensure if the node will boot
successfully. The client cannot suffer any data outage.
Which command would you use to perform the giveback?
(Node-1) is currently waiting for giveback. However, it is ensure if the node will boot
successfully. The client cannot suffer any data outage.
Which command would you use to perform the giveback?
A. CLUSTER::> storage failover giveback -ofnode Node-1 -only-cfo-aggregates
B. CLUSTER::> storage failover giveback -fromnode Node-2
C. CLUSTER::> storage failover giveback -ofnode Node-1 -require-partner-waiting false
D. CLUSTER::> storage failover giveback -ofnode Node-1 -override-vetoes true
Answer: C
Question #9 (Topic: )
Click the Exhibit tab.
[Netapp-NS0-191-8.0/Netapp-NS0-191-6_2.png]
The customer configured an SVM called NewSVM for NFS, configured the volume,
vol_nfs, mounted at /vol_nfs, and set up NFSv3 as shown in the exhibit. However, if
they try to mount from the client with IP address 192.168.10.10, they receive a permission
denied error.
In this scenario, which action will solve the error condition?
[Netapp-NS0-191-8.0/Netapp-NS0-191-6_2.png]
The customer configured an SVM called NewSVM for NFS, configured the volume,
vol_nfs, mounted at /vol_nfs, and set up NFSv3 as shown in the exhibit. However, if
they try to mount from the client with IP address 192.168.10.10, they receive a permission
denied error.
In this scenario, which action will solve the error condition?
A. Add a rule to the defaultexport policy to include the-clientmatch 192.168.10.0/24parameter.
B. Stop and start NewSVM.
C. Associate a correct export policy to the root volume (/) of NewSVM.
D. Configure the default route for NewSVM correctly.
Answer: B
Question #10 (Topic: )
Click the Exhibit tab.
[Netapp-NS0-191-8.0/Netapp-NS0-191-7_2.png]
[Netapp-NS0-191-8.0/Netapp-NS0-191-7_3.png]
A customer receives the AutoSupport messages shown below.
[?] Sat Aug 23 13:00:27 PDT [hostname: env_mgr: callhome.c.fan.fru.fault:error]: Call
home for CHASSIS FAN FRU FAILED: SysFan3 F2
[?] Sat Aug 23 13:00:32 PDT [hostname: env_mgr: monitor.chassisFan.ok:notice]: Chassis
fan Sysfan3 F2 is ok
The output of the sysconfig -a command is shown in the exhibit.
In this scenario, what would you do to solve this problem?
[Netapp-NS0-191-8.0/Netapp-NS0-191-7_2.png]
[Netapp-NS0-191-8.0/Netapp-NS0-191-7_3.png]
A customer receives the AutoSupport messages shown below.
[?] Sat Aug 23 13:00:27 PDT [hostname: env_mgr: callhome.c.fan.fru.fault:error]: Call
home for CHASSIS FAN FRU FAILED: SysFan3 F2
[?] Sat Aug 23 13:00:32 PDT [hostname: env_mgr: monitor.chassisFan.ok:notice]: Chassis
fan Sysfan3 F2 is ok
The output of the sysconfig -a command is shown in the exhibit.
In this scenario, what would you do to solve this problem?
A. Update Data ONTAP to 8.1.4 at the latest patch level.
B. Update the Service Processor firmware.
C. Replace the fan.
D. Disconnect the controller from the mains, wait two minutes, and re-connect it in the next maintenance window.
Answer: B