Dell E20-822 - CLARiiON Solutions Expert Exam for Storage Administrators Exam
Page: 1 / 24
Total 120 questions
Question #1 (Topic: Topic 0)
A customer has an OLTP and backup application running on their server. The customer
wants to control the bandwidth used by the backup application to 40 MB/s and their OLTP
application response time to 7 ms. Navisphere Quality of Service Manager (NQM) is
suggested as a solution. Which policies, I/O class, and control methods should be created?
wants to control the bandwidth used by the backup application to 40 MB/s and their OLTP
application response time to 7 ms. Navisphere Quality of Service Manager (NQM) is
suggested as a solution. Which policies, I/O class, and control methods should be created?
A. A policy and I/O class for each application Set both control methods to Cruise Control Run both policies together
B. A policy and I/O class for each application Set the backup control method to Limits Set the OLTP to Limits Run both policies together
C. A policy to include two I/O classes Set both control methods to Limits Run the policy
D. A policy to include two I/O classes Set the control method on the OLTP application to Cruise Control Backup the application to Limits Run the policy
Answer: C
Question #2 (Topic: Topic 0)
A customer implemented MirrorView/A as part of a disaster recovery solution. The RPO for
the MirrorView/A LUNs is 2 hours. The customer has a new requirement for a local replica
of the data to be made available every 2 hours. There should be minimal performance
impact. An automated solution using Navisphere Secure CLI is proposed. How should the
Navisphere Secure CLI be used to make the data copies?
the MirrorView/A LUNs is 2 hours. The customer has a new requirement for a local replica
of the data to be made available every 2 hours. There should be minimal performance
impact. An automated solution using Navisphere Secure CLI is proposed. How should the
Navisphere Secure CLI be used to make the data copies?
A. Make a snapshot of the primary image each time an update cycle starts.
B. Make two clones of the primary image and rotate every 2 hours.
C. Make two clones of the primary image and rotate every 4 hours.
D. Make two snapshots of the primary image and rotate every 2 hours.
Answer: A
Question #3 (Topic: Topic 0)
A storage administrator has a performance problem with a HP-UX host attached to a
CLARiiON. Navisphere Analyzer is enabled and statistics are being collected with default
settings. The storage administrator collects a CAP report from the CLARiiON and does a
health check. No problems are reported. What are the next steps in troubleshooting the
problem?
CLARiiON. Navisphere Analyzer is enabled and statistics are being collected with default
settings. The storage administrator collects a CAP report from the CLARiiON and does a
health check. No problems are reported. What are the next steps in troubleshooting the
problem?
A. Review the CLARiiON SP event logs Retrieve the NAR files and review the Performance Summary Re-create the problem and capture the iograph data
B. Review the CLARiiON SP event logs Retrieve the NAR files and review the Performance Summary Re-create the problem and capture the iostat data
C. Review the CLARiiON SP event logs Retrieve the NAR files and review the Performance Summary Re-create the problem and capture the perfmon data
D. Review the CLARiiON SP event logs Retrieve the NAR files and review the Performance Summary Re-create the problem and capture the perfstat data
Answer: B
Question #4 (Topic: Topic 0)
A customer has two 50 GB MirrorView/S mirrored LUNs between two CX3-40s without a
Write Intent Log. LUN1 is on SP A and LUN2 is on SP B. The two CX3-40s are connected
via dedicated Fibre Channel links.
During the nightly maintenance window, the connection between SP A on the local array
and SP A on the remote array is lost for 2 minutes. SP B is unaffected. When the customer
logs in the next morning, they notice that LUN1 has a status of "attention" and is still
fractured.
What caused this behavior?
Write Intent Log. LUN1 is on SP A and LUN2 is on SP B. The two CX3-40s are connected
via dedicated Fibre Channel links.
During the nightly maintenance window, the connection between SP A on the local array
and SP A on the remote array is lost for 2 minutes. SP B is unaffected. When the customer
logs in the next morning, they notice that LUN1 has a status of "attention" and is still
fractured.
What caused this behavior?
A. Auto recovery is not possible on the CLARiiON
B. Missing Write Intent Log
C. Recovery policy is set to Manual
D. SP A set the affected front-end FC port administratively down
Answer: C
Question #5 (Topic: Topic 0)
A storage administrator has attached a HP-UX host to a CLARiiON environment consisting
of three CLARiiON arrays. The HP-UX host has six HBAs installed. The administrator will
not be using PowerPath as the failover software.
The administrator has run the following command to add a path from an HBA to the storage
group for the server:
naviseccli address cx1-spa storagegroup etpath name HPUX1 bauid
20:00:00:E0:8B:13:6A:92:21:00:00:E0:8B:13:6A:92 p a pport 0 ip 10.10.11.134 ost HPUX1-
failovermode 3 rraycompath 0
The command completes successfully; however, the host is not showing the devices when
oscan is run. How can the storage administrator fix this error?
of three CLARiiON arrays. The HP-UX host has six HBAs installed. The administrator will
not be using PowerPath as the failover software.
The administrator has run the following command to add a path from an HBA to the storage
group for the server:
naviseccli address cx1-spa storagegroup etpath name HPUX1 bauid
20:00:00:E0:8B:13:6A:92:21:00:00:E0:8B:13:6A:92 p a pport 0 ip 10.10.11.134 ost HPUX1-
failovermode 3 rraycompath 0
The command completes successfully; however, the host is not showing the devices when
oscan is run. How can the storage administrator fix this error?
A. Failovermode set to 0
B. Failovermode set to 1
C. Failovermode set to 2
D. Failovermode set to 4
Answer: A