VMware 2V0-41.24 - VMware NSX 4.X Professional V2 Exam

Question #6 (Topic: Exam A)
As part of an organization’s IT security compliance requirement, NSX Manager must be configured for 2FA (two-factor authentication).
What should an NSX administrator have ready before the integration can be configured?
A. Active Directory LDAP integration with ADFS B. VMware Identity Manager with NSX added as a Web Application C. VMware Identity Manager with an OAuth Client added D. Active Directory LDAP integration with OAuth Client added
Answer: B
Question #7 (Topic: Exam A)
What should an NSX administrator check to verify that VMware Identity Manager integration is successful?
A. From the NSX UI the status of the VMware Identity Manager Integration must be “Enabled”. B. From the NSX CLI the status of the VMware Identity Manager Integration must be “Configured”. C. From VMware Identity Manager the status of the remote access application must be green. D. From the NSX UI the URI in the address bar must have “local=false” part of it.
Answer: A
Question #8 (Topic: Exam A)
An administrator has been tasked with implementing the SSL certificates for the NSX Manager Cluster VIP.
Which is the correct way to implement this change?
A. Send an API call to https://<nsx-mgr>/api/vl/cluster/api-certificate?action=set_cluster_certificate&certificate_id=<certificate_id> B. Send an API call to https://<nsx-mgr>/api/vl/node/services/http?action=apply_certificate&certificate_id=<certificate_id> C. SSH as admin into the NSX manager with the cluster VIP IP and run nsxcli cluster certificate node install <certificate_id> D. SSH as admin into the NSX manager with the cluster VIP IP and run nsxcli cluster certificate vip install <certificate_id>
Answer: D
Question #9 (Topic: Exam A)
An administrator wants to validate the BGP connection status between the Tier-0 Gateway and the upstream physical router.
What sequence of commands could be used to check this status on NSX Edge node?
A. - enable <LR-D>
- get vrf <ID>
- show bgp neighbor
B. - get gateways
- vrf <number>
- get bgp neighbor
C. - set vrf <ID>
- show logical-routers
- show <LR-D> bgp
D. - show logical-routers
- get vrf
- show ip route bgp
Answer: A
Question #10 (Topic: Exam A)
What is VMware’s recommendation for the minimum MTU requirements when planning an NSX deployment?
A. MTU should be set to 1700 or greater across the data center network including inter-data center connections. B. MTU should be set to 1500 or less only on inter-data center connections. C. Configure Path MTU Discovery and rely on fragmentation. D. MTU should be set to 1550 or less across the data center network including inter-data center connections.
Answer: A
Download Exam
Page: 2 / 17
Total 85 questions